Review




Structured Review

Formlabs Inc elastic 50a–replisil
Elastic 50a–Replisil, supplied by Formlabs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/elastic+50a+replisil/elastic+50a+replisil/pm36013710-332-2-25
Average 90 stars, based on 1 article reviews
elastic 50a–replisil - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

other:

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin
Article Snippet: 90° without prestress (control group) , Formlabs Elastic 50A-Replisil 9N , 0.17 ± 0.034 , 0.37 ± 0.08 , 0.44 ± 0.071.

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin.
Article Snippet: After the defective samples had been disposed of, n = 25 samples were tested of each material (Replisil 9N, Formlabs Elastic 50A) and setup (90◦ prestress, 90◦ no prestress, 45◦ no prestress) combination.

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin.
Article Snippet: The first force maximum ∆F1 and the following maximum force ∆F2 are in N. Test Series ∆E (N/mm) ∆F1 (N) ∆F2 (N) 90° with prestress Formlabs Elastic 50A‐Replisil 9N 0.15 ± 0.044 0.4 ± 0.076 0.68 ± 0.098 45° without prestress Formlabs Elastic 50A‐Replisil 9N 0.14 ± 0.038 0.13 ± 0.145 0.44 ± 0.128 90° without prestress (control group) Formlabs Elastic 50A‐Replisil 9N 0.17 ± 0.034 0.37 ± 0.08 0.44 ± 0.071 4.

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin.
Article Snippet: After the defective samples had been disposed of, n = 25 samples were tested of each ma‐ terial (Replisil 9N, Formlabs Elastic 50A) and setup (90° prestress, 90° no prestress, 45° r str ss) c i ti . is r s lt i t t l t st s l c t f . Figure 4.

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin
Article Snippet: 45° without prestress , Formlabs Elastic 50A-Replisil 9N , 0.14 ± 0.038 , 0.13 ± 0.145 , 0.44 ± 0.128.

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin
Article Snippet: After the defective samples had been disposed of, n = 25 samples were tested of each material (Replisil 9N, Formlabs Elastic 50A) and setup (90° prestress, 90° no prestress, 45° no prestress) combination.

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin
Article Snippet: Additionally, each result of the Replisil 9N was subtracted from each result of the Formlabs Elastic 50A for all three parameters in the according test series, resulting in a 25 × 25 Matrix and 625 differences.

Proximity Ligation Assay:

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin.
Article Snippet: .. Manufacturer Product Formlabs Elastic 50A resin Silconic Replisil 9N A/B Prusa Prusament PLA (various colors) Braun Original Perfusor Syringe 50 ml Mersilene EH7350 75 cm suture material VYGON special cannula REF 219.14 1.4 × 70 mm Gedore 570020 Punch 20 mm Lvcky 60 mL transparent polypropylene plastic cups with stirrers - locknuts DIN 985 A2 M 5/10 - cylinder screws DIN 912-8.8 VZ - washers DIN 125 A2 M 5/20 SAV LP GmbH isopropanol Pharma SAV Gatt-Koller GmbH isopropanol p.A. ..



Similar Products

90
Formlabs Inc elastic 50a–replisil
Elastic 50a–Replisil, supplied by Formlabs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/elastic+50a+replisil/elastic+50a+replisil/pm36013710-332-2-25
Average 90 stars, based on 1 article reviews
elastic 50a–replisil - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Formlabs Inc elastic 50a-replisil 9n
All three setups during the conduction of a test. The 90° prestressed setup testing a sample of <t>Replisil</t> <t>9N</t> ( a ). The 45° non-prestressed setup testing a sample of the Formlabs Elastic <t>50A</t> ( b ). The 90° non-prestressed control setup testing a sample of the Replisil 9N ( c ).
Elastic 50a Replisil 9n, supplied by Formlabs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/elastic+50a+replisil/elastic+50a+replisil+9n/pmc09415758-48-5-4
Average 90 stars, based on 1 article reviews
elastic 50a-replisil 9n - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Formlabs Inc elastic 50a‐replisil
All three setups during the conduction of a test. The 90° prestressed setup testing a sample of <t>Replisil</t> <t>9N</t> ( a ). The 45° non-prestressed setup testing a sample of the Formlabs Elastic <t>50A</t> ( b ). The 90° non-prestressed control setup testing a sample of the Replisil 9N ( c ).
Elastic 50a‐Replisil, supplied by Formlabs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/elastic+50a+replisil/elastic+50a+replisil/pm36013710-332-24-25
Average 90 stars, based on 1 article reviews
elastic 50a‐replisil - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


All three setups during the conduction of a test. The 90° prestressed setup testing a sample of Replisil 9N ( a ). The 45° non-prestressed setup testing a sample of the Formlabs Elastic 50A ( b ). The 90° non-prestressed control setup testing a sample of the Replisil 9N ( c ).

Journal: Materials

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin

doi: 10.3390/ma15165575

Figure Lengend Snippet: All three setups during the conduction of a test. The 90° prestressed setup testing a sample of Replisil 9N ( a ). The 45° non-prestressed setup testing a sample of the Formlabs Elastic 50A ( b ). The 90° non-prestressed control setup testing a sample of the Replisil 9N ( c ).

Article Snippet: 45° without prestress , Formlabs Elastic 50A-Replisil 9N , 0.14 ± 0.038 , 0.13 ± 0.145 , 0.44 ± 0.128.

Techniques:

Pictures of both sample types. The Replisil 9N sample with a macroscopic air enclosure in the upper left quarter ( a ). The Formlabs Elastic 50A sample with vertical and parallel arranged grooves ( b ).

Journal: Materials

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin

doi: 10.3390/ma15165575

Figure Lengend Snippet: Pictures of both sample types. The Replisil 9N sample with a macroscopic air enclosure in the upper left quarter ( a ). The Formlabs Elastic 50A sample with vertical and parallel arranged grooves ( b ).

Article Snippet: 45° without prestress , Formlabs Elastic 50A-Replisil 9N , 0.14 ± 0.038 , 0.13 ± 0.145 , 0.44 ± 0.128.

Techniques:

Mean test results of the three parameters E, F 1 and F 2 with standard deviations. The gradient of the linear graph part E is in N/mm. The first force maximum F 1 and the following maximum force F 2 are in N.

Journal: Materials

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin

doi: 10.3390/ma15165575

Figure Lengend Snippet: Mean test results of the three parameters E, F 1 and F 2 with standard deviations. The gradient of the linear graph part E is in N/mm. The first force maximum F 1 and the following maximum force F 2 are in N.

Article Snippet: 45° without prestress , Formlabs Elastic 50A-Replisil 9N , 0.14 ± 0.038 , 0.13 ± 0.145 , 0.44 ± 0.128.

Techniques:

Mean test results of the differences of the three parameters ∆E, ∆F 1 and ∆F 2 with standard deviations. The gradient of the linear graph part ∆E is in N/mm. The first force maximum ∆F 1 and the following maximum force ∆F 2 are in N.

Journal: Materials

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin

doi: 10.3390/ma15165575

Figure Lengend Snippet: Mean test results of the differences of the three parameters ∆E, ∆F 1 and ∆F 2 with standard deviations. The gradient of the linear graph part ∆E is in N/mm. The first force maximum ∆F 1 and the following maximum force ∆F 2 are in N.

Article Snippet: 45° without prestress , Formlabs Elastic 50A-Replisil 9N , 0.14 ± 0.038 , 0.13 ± 0.145 , 0.44 ± 0.128.

Techniques:

List of the used materials.

Journal: Materials

Article Title: Needle Penetration Simulation: Influence of Penetration Angle and Sample Stress on the Mechanical Behaviors of Polymers Applying a Cast Silicone and a 3D-Printed Resin

doi: 10.3390/ma15165575

Figure Lengend Snippet: List of the used materials.

Article Snippet: 45° without prestress , Formlabs Elastic 50A-Replisil 9N , 0.14 ± 0.038 , 0.13 ± 0.145 , 0.44 ± 0.128.

Techniques: